Waterproof fire rated trafficable sound attenuating insulating air wind seismic and watertight building expansion joints and precompressed hybrid sealants.
Florida roof deck adhesive retrofit.
Permitted under the 2004 code or newer.
For houses with both hip and gable roof ends the priority shall be to retrofit the gable end roof to wall connections unless the width of the hip end is more than 1 5 times greater than the width of the gable end.
Nails shall be corrosion resistant and not less than 11 gage 5 16 inch 11 mm head and of sufficient length to penetrate the deck not less than 3 4 inch 19 mm or through the thickness of the deck whichever is less or in accordance with the frsa tri florida high wind concrete and clay roof tile installation manual fifth edition where.
Having a roofing professional evaluate your retrofit options and perform the retrofit is a good idea for most homeowners.
I can highly recommend them they were punctual professional and cleaned up everything after completing the job.
Adhesive and sealant council project report adhesive systems for roof.
Florida retrofit made our roof hurricane ready this week.
Expansion joints and construction sealants.
10 of 11 adhesives tested to a failure pressure of at least 150 psf retrofit applications of adhesives recommended only as a temporary measure until re roofing because of unknown effects of attic environmental conditions on the strength of adhesives sources.
Deck re nailing fbc existing building section 706 7 establishes the requirement that the roof decking is to be re nailed.
Board roof decking secured with at least two 8d nails into roof framing members shall be.
Structures that already comply are exempt from this requirement i e.
201 1 are deemed to comply with the requirements of section 507 2 2 of the 2004 florida building code existing building.
706 7 when a roof covering on an existing site built single family residential.
The typical foam insulation or adhesive available at a home improvement store will not work for this type of application.
The adhesives need to be approved for tile installations able to withstand high heat.
You can improve the uplift resistance of the roof deck from the attic without removing the roof covering.
Emseal s manufacturing plants are open and operating at full capacity.
Expansion joint covers and sealants for the built environment.
A sealed and insulated roof deck can t dry inward to the attic if the roofing happens to let water.
Applying closed cell spray insulation to the underside of a roof deck at the sheathing to truss connection can double or triple the strength of the assembly boosting the roof sheathing s resistance to wind uplift in a hurricane.
Seems when my house was built the trusses were not properly secure to the concrete blocks.
They really know what they are doing and the insurance discount is huge.